Anodal® MS-1 New liquid medium and high temperature liquid sealant
Classification:
Tag:
Product Details
Anodal® MS-1 New
It is a medium to high temperature nickel-containing liquid sealing agent.
Anodal® MS-1 New
It can suppress stain formation during hot water sealing, achieving excellent sealing quality.
Anodal® MS-1 New
Developed by Clariant and patented in several industrial countries.
1. Performance
Appearance: Green transparent solution
Solubility: Miscible with water in any proportion
Storage period: Under sealed original packaging
0-40°C
for at least
1 year.
Safety data: See safety data sheet (
)
3
2. Application range
Suitable for both dyed aluminum parts and parts that have been anodized but not dyed.
MSDS
3. Application conditions
Usage amount
Anodal® MS-1 New
The usage amount mainly depends on the quality of the water and the type of oxide film, preferably using deionized water.
The following amounts are recommended as a reference:
15~30ml/l
Sealing temperature
At least
80~95°C
The higher the temperature, the better the sealing quality.
Sealing time
Recommended sealing time
1~2min/µm
up to
3min/µm
To ensure the best sealing quality, when preparing the sealing bath solution or during use, the pH value should be checked and adjusted as required by adding diluted ammonia or acetic acid.
Stirring
Anodal MS-1 New
contains surfactant components, so it is advisable to avoid aeration stirring during use.
pH
5.5-6.0
Mechanical stirring or circulating water stirring is recommended.
pH
4. Preparation and maintenance of sealing bath solution
Sealing bath body
Should be made of acid-resistant materials, preferably stainless steel.
Water quality
It is best to use deionized water for sealing, which ensures the best sealing effect without stains. Softened tap water can also be used,
but the water must not contain sealing contaminants such as phosphates, fluorides, and silicates, as these substances can delay or even hinder the sealing process.
For example, using tap water for sealing holes may not form sealing stains on the surface,
but undissolved mineral salts in the water can form dry deposits.
Using deionized water to prepare the sealing solution, which does not contain sealing contaminants, will not form sealing stains. When the sealed items are removed from the bath solution, the water quickly drains away, preventing deposits from forming in the air.
Bath solution analysis
The following method can quickly analyze the concentration of
®
MS-1 New
in the bath solution.
Principle
Determine the sealing agent using complexometric titration.
Reagent: -0.1M EDTA
Disodium (Ethylenediaminetetraacetic acid disodium salt)
Anodal
Dissolve
disodium ethylenediaminetetraacetate in pure water, dilute to the desired concentration in a volumetric flask.
A pre-made solid can also be used.
Indicator: Purple uric acid amine
with
Anodal
Dissolve
disodium ethylenediaminetetraacetate in pure water, dilute to the desired concentration in a volumetric flask.
A pre-made solid can also be used.
100 g
sodium chloride, mixed and ground as finely as possible.
About
25%
37.2g
pure ammonia solution
1000ml
Titrate
Take the filtered clear
0.1M
sealing agent bath solution into a beaker,
1L
and add
EDTA
pure
-
water. Add a small amount of indicator (about
1g
50mg)
and
ammonia.
Use
-
大约
25%
纯氨水溶液
滴定
吸取
25ml
已过滤澄清的
Anodal
Dissolve
disodium ethylenediaminetetraacetate in pure water, dilute to the desired concentration in a volumetric flask.
封闭剂槽液到
250ml
烧杯中
,
并加入
50ml
纯
水。加少量的指示剂(大约
50mg)
和
15ml
氨水。用
0.1MEDTA
Disodium titration, starting from
slight turbidity, the brownish-yellow solution changes to purple until
EDTA
when disodium is in excess, the color will turn blue-violet.
色)。
Usage:
a
ml 0.1M EDTA
disodium
Calculate
Anodal
Dissolve
disodium ethylenediaminetetraacetate in pure water, dilute to the desired concentration in a volumetric flask.
concentration (volume ratio)